What is the problem in this scenario?

A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vPC to the Nexus 500 switches. After logging in to the switches, you notice that all vPC member ports on the secondary vPC peer switch are down. The vPC peer keepalive is still operational.What … Read more

Which action must the administrator perform to solve the problem?

An administrator has a FlexPod solution with VMware vSphere. The administrator is migrating all network traffic from standard switches to vSphere distributed switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vSwitch3. A new distributed switch called dvSwitch_VM is created and new distributed port groups are … Read more

Which power policy should you configure in UCS Manager?

A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU.In this scenario, which power policy should you configure in UCS Manager?Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/ b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html Question: Which power policy should you configure in UCS Manager? … Read more

Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains?

Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains?Reference https://www.cisco.com/c/en/us/products/servers-unified-computing/ucs-central-software/index.html Question: Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains? Options: UCS Manager UCS Director UCS Central UCS Performance Manager Correct Answer The Correct Answer for this Question is UCS Central

Which pool is needed to configure the vHBA templates?

An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster.Which pool is needed to configure the vHBA templates? Question: Which pool is needed to configure the vHBA templates? Options: WWPN pool MAC pool IQN pool WWNN pool Correct Answer The Correct Answer for this Question … Read more

Which set of commands maps VLAN 100 to VSAN 100?

Which set of commands maps VLAN 100 to VSAN 100?Nexus 5000-A (config) # vlan 100Nexus 5000- A (config-vlan_ #fcoe vsan 100Nexus 5000-B (config) # vsan databaseNexus 5000-B (config-vsan)# vsan 100Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100Nexus 5000-B (config) # vsan databaseNexus 5000-A (config)# vsan 100Nexus 5000-A (config-vsan) # fcoe vsan 100Nexus 5000-B (config-vsan)# vsan … Read more

Which virtual disk should you create to meet these requirements?

You are deploying a new virtual machine (VM). Your customer requires that the VM cannot reserve space on the VMFS filesystem, and the VM can only consume blocks when data is written to disk from and within the VM/Guest OS.Which virtual disk should you create to meet these requirements?Reference https://communities.vmware.com/thread/534974 Question: Which virtual disk should … Read more

What must you do to enable VAAI for NFS on that ESXi host?

You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.In this scenario, what must you do to enable VAAI for NFS on that ESXi host?Reference https://greatwhitetec.com/2014/12/29/deploying-netapp-nfs-plug-in-for-vmware-vaai/ Question: What must … Read more

What is a cause for this failure?

You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.What is a cause for this failure? Question: What is a cause for this failure? Options: The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster. The cluster LIFs … Read more

Which set of commands will correct this problem?

You run NetApp Config Advisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.Which set of commands will correct this problem? Question: Which set of commands will correct this problem? Options: network interface modify-node netapp-01 “port e0a “flowcontrol “admin none network interface modify … Read more